User Seal Check Procedures

Introduction

The individual who uses a tight-fitting respirator is to perform a user seal check to ensure that an adequate seal is achieved each time the respirator is put on.  Either the positive and negative pressure checks listed in the following instructions, or the respirator manufacturer’s user seal check method shall be used.  User seal checks are not a substitute for qualitative or quantitative fit tests

 

Seal Check Instructions

Facepiece Positive and/or Negative Pressure Tests

  1. Positive pressure check.  

    Close of the exhalation valve and exhale gently into the facepiece. The face fit is considered satisfactory if a slight positive pressure can be built up inside the facepiece without any evidence of outward leakage of air at the seal.  For most respirators this method of leak testing requires the wearer to first remove the exhalation valve cover before closing of the exhalation valve and then carefully replacing it after the test.

  2. Negative pressure check  

    Close off the inlet opening of the canister or cartridge(s) by covering with the palm of the hand(s) or by replacing the filter seal(s), inhale gently so that the facepiece collapses slightly and hold the breath for ten seconds. The design of the inlet opening of some cartridges cannot be effectively covered with the palm of the hand.  The test can be performed by covering the inlet opening of the cartridge with a thin latex or nitrile glove.  If the facepiece remains in its slightly collapsed condition and inward leakage of air is detected, the tightness of the respirator is considered adequate.

  3. Manufacturer’s Recommended User Seal Check

The respirator manufacturer’s recommended procedures for performing a user seal check may be used instead of the positive and/or negative pressure check procedures provided that the employer demonstrates that the manufacturer’s procedures are equally effective.